Theta/Theta Geometry Torque Motor Direct Drive Plug & Scan Modular Design Dectris HPC Detector Residual Stress & Texture Analysis

GNR Explorer is a modular X-ray diffractometer with Theta/Theta geometry and torque-motor direct-drive optics. It supports powder diffraction, thin film characterization, residual stress measurement, and texture analysis within a single configurable platform.

±0.01°
Angular accuracy
278°
2θ scan range (−110° / +168°)
3 kW
X-ray generator power
35+ Yrs
GNR manufacturing experience
GNR Explorer XRD Diffractometer
🔷
Theta/Theta
Goniometer geometry
🎯
±0.01°
Angular accuracy (full 2θ range)
🔬
0.0001°
Minimum step size
3 kW
X-ray generator power (opt. 4 kW)
📐
−110° / +168°
2θ scan range
📡
SDD · 1D · 2D
Supported detector types
400–600 mm
Goniometer circle diameter
<1 mSv/yr
Radiation safety limit
GNR Explorer — Eulerian Cradle for Residual Stress and Texture Analysis

No Gears, No Belts,
No Maintenance

The torque-motor direct-drive system eliminates gears, belts, and reducers from the goniometer entirely. Optical encoders guarantee ±0.01° angular accuracy across the full 2θ range.

🎯
Direct-Drive Torque Motor
The load couples directly to the motor shaft. Without gears or belts, there is no backlash or mechanical hysteresis. Long-term repeatability is built into the architecture, not achieved through calibration workarounds.
🔷
Sample Stays Horizontal
In Theta/Theta geometry, both the tube and detector arms rotate while the sample remains stationary and level. Loose powders, liquids, and heavy specimens require no special fixturing.
🔬
NIST-Verified Performance
Every instrument undergoes factory testing with NIST SRM Alumina 1976, Lanthanum Hexaboride 660, and Silicon Powder 640 certified reference materials, and ships with a calibration certificate.
GNR Explorer — 1D and 2D Hybrid Photon-Counting Detectors

Fast Data,
Low Noise

GNR Explorer supports Dectris 1D HPC, Advacam MiniPix-TPX3 2D, and Silicon Drift Detector configurations. Measurement times drop from hours to minutes.

📡
Dectris 1D HPC Detector
640 pixels, 50 µm pixel size, dynamic count rate up to 10¹⁰ counts/s. Noise-free hybrid photon counting technology delivers high-quality diffractograms in a fraction of the time required by conventional detectors.
📷
Advacam MiniPix-TPX3 2D Detector
256 × 256 pixels, 55 µm pixel pitch. Position, energy, and arrival time are recorded simultaneously for each photon. Full 2D diffraction patterns for texture and residual stress measurements.
🧪
Silicon Drift Detector (SDD)
10–170 mm² active area, ≤129 eV energy resolution at Mn Kα (1 µs shaping time). Combines high count rates with high resolution for EDXRF and TXRF spectroscopy alongside XRD measurements.
GNR Explorer — Non-ambient X-Ray Diffraction Configuration

In-situ Measurements
at Real Process Conditions

GNR Explorer monitors phase transitions, thermal expansion, and chemical transformations under real process conditions using high/low-temperature and humidity-controlled accessories.

🌡
Temperature Chambers
High- and low-temperature configurations for in-situ diffraction beyond ambient conditions. Sintering, polymorphic transitions, and thermal decomposition can all be tracked in real time.
💧
Humidity & Gas Control
Hydration-dehydration cycling in humidity-controlled environments and reaction monitoring under controlled gas atmospheres. Suited for catalyst and battery materials research.
Full Software Integration
Non-ambient accessories operate under software control; temperature ramps, dwell times, and measurement sequences are all programmed from the data-collection interface.

One Platform,
Broad Analytical Reach

Phase Analysis
Qualitative and quantitative phase identification in polycrystalline materials across mineralogy, ceramics, and chemicals. Rietveld, RIR, and E-Calibration methods for weight-fraction calculation.
💊
Pharmaceutical Industry
Crystallinity index and amorphous phase quantification of active pharmaceutical ingredients (APIs). Polymorphic screening and compatibility testing. OSHA/NIOSH-compliant crystalline silica determination.
🔬
Thin Film & Coatings
XRR for layer thickness (1–200 nm), density, and surface/interface roughness. Grazing-incidence diffraction (GID) for thin polycrystalline coating characterization with suppressed substrate signal.
🏭
Residual Stress & Texture
High-precision texture analysis with open Eulerian cradle and 2D detector. BEARTEX software for ODF calculation and pole figure generation from up to 100 pole figures.
🌱
Environmental Monitoring
Quantification of respirable crystalline silica (quartz, cristobalite) collected on air filters. Calibration against NIST SRM 1878; compliant with OSHA and NIOSH analytical methods.
Geology & Mining
Mineral phase analysis in rock and ore specimens. Basal reflection detection for clay mineralogy. Phase purity control for ore beneficiation and processing quality assurance.
🏺
Aluminium Production
Real-time monitoring of electrolytic bath parameters — Bath Ratio (BR) and Excess AlF₃ — using a 15-position automatic sample changer with simultaneous SDD elemental analysis.
Nuclear Applications
Glove-box integration with X-ray and radiation shielding for safe phase characterization of plutonium and transuranium element-containing specimens.
🔭
Microdiffraction
Mono- and polycapillary collimators reduce the beam spot to 0.1 mm. Suitable for forensic science specimens, small single-crystal fragments, and micro-scale structural analysis.
🌡
Non-ambient Experiments
High/low-temperature and humidity-controlled chambers enable real-time monitoring of polymorphic transitions, sintering, and thermal decomposition under process conditions.
🔋
Battery & Energy Materials
Crystal phase verification of cathode and anode materials for Li-ion, solid-state, and redox flow battery applications. In-situ charge/discharge cycling measurements.
🏗
Cement & Binders
Quantitative analysis of Portland clinker phases (Alite, Belite, Aluminate, Ferrite). Pozzolanic reactivity monitoring and waste stabilisation quality control.

A Holder for Every
Sample Geometry

GNR Explorer accommodates flat, circular, and specialty holders for powders, bulk specimens, thin films, and air-sensitive samples. All holders attach directly to the standard goniometer adapter for fast changeover.

GNR Explorer Chi-Phi-Z sample stage — multi-axis positioning
GNR Explorer capillary spinner sample holder
GNR Explorer spinning multi-sample holder
Flat Sample Holders (44 mm length)
HolderMaterialCavityDepth
Front-loadingAluminium20 × 20 mm1 mm
Back-loadingAluminium20 × 20 mm1.9 mm
Front-loadingPMMA20 × 20 mm0.2 / 0.5 mm
Si zero backgroundAluminiumØ 24.7 mm0.5 / 0.1 mm
Circular Holders — Herzog Press (OD: 51.5 mm)
HolderMaterialCavityDepth
Back-loadingSteelØ 24.7 mm2.5 mm
Side-loadingSteelØ 24.7 mm2 mm
Si zero backgroundSteelØ 24.7 mm0.2 mm
Reflection/transmission (air-sensitive)SteelØ 20 mm0.5 / 1 mm
Clay oriented total mountSteel + Glass37 × 37 mm²2.5 mm
Solid specimenSteelØ 45 mm7 mm
Air monitoring filterSteelØ 25.7 mm
Air-sensitive (Kapton 8 µm)Steel + TeflonØ 25 mm1.5 mm

Custom-optimised sample holders are also available on request.

Common Questions

The GNR Explorer scans from −110° to +168° 2θ. The torque-motor optical-encoder drive system maintains angular accuracy better than ±0.01° across this entire range. The minimum step size of 0.0001° provides sufficient resolution for precise lattice parameter determination.

In Theta/Theta geometry, both the X-ray tube and detector arm rotate while the sample stays horizontal and stationary. This is particularly suited for loose powders, liquids, thin films, and heavy specimens — no special mounting or fixturing is required to keep the sample in the beam.

Plug & Scan means that optics, detectors, and sample stages can be exchanged without realignment. The system can be purchased in an entry-level XRPD configuration and expanded later with thin-film optics, an Eulerian cradle, or alternative detectors — each accessory installs and scans immediately.

Three detector options are available: Dectris 1D HPC (640 pixels, 50 µm) for fast, noise-free powder diffraction; Advacam MiniPix-TPX3 2D (256 × 256 pixels, 55 µm) for full 2D pattern capture and texture analysis; and Silicon Drift Detector for simultaneous EDXRF/TXRF spectroscopy alongside XRD data collection.

XRR and GID measurements require the parabolic mirror monochromator, piezoelectric sample stage, and knife-edge collimator combination. These are supplied as optional accessories and, thanks to the Plug & Scan architecture, can be used alongside the standard XRPD configuration without separate realignment.

Anka Analitik A.Ş. is the authorized distributor for GNR products in Türkiye. For a quotation, demonstration request, or technical consultation, please contact us by phone, e-mail, or WhatsApp.

Request a Quote for
GNR Explorer

Contact our specialist team for technical consultation, a demonstration, or pricing information. Over 25 years of analytical instrumentation expertise at your service.

📞
+90 (216) 577 52 96Call us
info@ankaanalitik.com.trSend an e-mail
💬
WhatsApp+90 549 252 76 46
📍
Kadıköy, İstanbul19 Mayıs Mah. Sumer Sok. Sumko Sitesi A7 Blok No:3CL
Quote / Information Request